Endura™ MD Triplex Booster Control Panel

Triplex Pressure Booster Control Panel

NEMA 1 indoor rated

The Endura­™ MD triplex booster control panel features the VFDC-4100 controller for commercial pressure booster applications using (3) Variable Frequency Drives (VFDs).

The Endura™ MD Triplex Booster panel is designed to control three 3-phase pumps in constant pressure control applications, including booster pump, deep well submersible pump, and irrigation pump applications.  As flow and head conditions change in the pumping system, the VFD4100 controller is able to automatically control the pump speed and maintain a constant pressure.  

Panel de Control Endura™ MD Triplex Booster

Gabinete NEMA 1 para uso en interiores

El panel Endura™ MD Triplex Booster cuenta con el controlador VFDC-4100 para aplicaciones comerciales de refuerzo de presión utilizando (3) unidades de frecuencia variable (VFD).
El panel Endura™ MD Triplex Booster está diseñado para controlar tres bombas trifásicas en aplicaciones de control de presión constante, incluyendo bombas de refuerzo de presión, bombas sumergibles de pozo profundo y en aplicaciones de riego. A medida que las condiciones de flujo y cabeza cambian en el sistema de bombeo, el controlador VFDC-4100 es capaz controlar automáticamente la velocidad de la (s) bomba (s) y mantener una presión constante.

Incluye transductor de presión de 0-200 PSI (4-20 mA)

 

 

Endura™ MD Triplex Booster Control Panel

Standard Control Panel Features:

  • Painted steel, wall mounted single door enclosure; NEMA 1 indoor rated
  • (2) cooling fans with filters and adjustable thermostat
  • VFDC-4100 controller
    • Graphic screen display with LED back light
    • 4 arrow buttons for easy navigation and setup
    • System status display: operating pressure, set pressure, time/date, alarm with time date
    • Pump status display: pumps in use, lead pump, pump run/stop, pump speed, VFD fault, hour meter for each pump
    • Automatic alternation (cycle or timed based)
    • Password protection
  • Panel mounted Variable Frequency Drive (VFD) for each pump
  • Circuit breaker disconnect for each pump
  • 22mm Hand/Off/Auto switches for each pump
  • 22mm General Alarm red indicator activates on:
    • Pump fault
    • High pressure fault
    • Low suction pressure fault
  • 24 VDC power supply - NEC Class 2 operating overcurrent protection
  • Multi-tap 150 VA transformer 480/240/208:120 VAC
  • Terminal blocks for:
    • Main power
    • Pumps
    • Pressure transmitter
    • Low suction pressure switch
    • Remote enable 
    • Auxiliary alarm contacts
  • UL 508A Listed
  • 0-200 PSI pressure transmitter with 6m (20ft) cable

    Options:

  • Main circuit breaker disconnect with a through door disconnect mechanism - consult factory for pricing

 

 

Endura™ MD Triplex Booster Control Panel

Specifications:

For specifications on the Endura™ MD (Multiple Drives) Triplex Booster control panel, please contact the factory at 1-888-342-5753.

 

Available Downloads

Adobe Acrobat is a free download to view .pdfs

Visit our downloads section of this website for additional literature.

USA  French Canadian  Chinese

French  German  Italian  Spanish