SJE-Rhombus

SJE-Rhombus International Product Details

  • Product Info
  • Features
  • Specs
  • Downloads

Junior Super Single®

Mercury-Activated, Wide-Angle Pump Switch

Pump switches provide automatic pump control.

The Junior Super Single® pump switch is designed to directly control pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC in non-potable water, water and sewage applications.

Although the Junior Super Single® pump switch is not sensitive to rotation, it is affected by turbulence and should be mounted in a non-turbulent location.  It is not recommended for use with motor contactors or relays because the motor contactor or relay may experience chattering.  A Super Single® or Double Float® pump switch would operate more efficiently in these installations.

U.S. Patent No. 4,529,854 and 4,572,934

 

Junior Super Single®

Features:

  • Controls pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC
  • Adjustable pumping range of 16.5 - 48 cm (6.5 - 19 inches)
  • Includes standard mounting clamp and boxed packaging

Junior Super Single® Pump Switch Diagrams

Options:

  • For pump up or pump down applications as specified by part number
  • With a 120 VAC or 230 VAC piggy-back plug
  • Without a plug for direct wiring in 120 VAC or 230 VAC applications
  • In standard cable lengths of 3, 5, 6, or 10 meters (10, 15, 20, or 30 feet) - longer lengths available

UL Recognized, CSA Certified

Three Year Limited Warranty

 

 

Junior Super Single®

Specifications:

CABLE:
Flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE)

FLOAT:
7.14 cm diameter x 8.68 cm long (
2.81 inches diameter x  3.42 inches long) high impact, corrosion resistance, PVC housing for use in sewage and water up to 60oC (140oF)

MERCURY SWITCH:
Mercury-to-metal contacts, hermetically sealed in a steel capsule

ELECTRICAL:
120 VAC 50/50 Hz Single Phase:
Maximum Pump Running Current: 13 amps
Maximum Pump Starting Current: 40 amps
Recommended Pump HP: 373 W (1/2 HP) or less

230 VAC 50/50 Hz Single Phase:
Maximum Pump Running Current: 8 amps
Maximum Pump Starting Current: 20 amps
Recommended Pump HP: 746 W (1 HP) or less

NOTE: This switch must be used with pumps that provide integral thermal overload protection.

 